2× is the vibration that occurs twice per revolution of the shaft. It is called dominant when the second harmonic stands out clearly, sometimes even above 1×.
Characteristics
Twice per turn. Something is loading the rotor two times every revolution.
Often paired with 1×. Misalignment typically shows a strong 2× together with a 1×, and frequently raised axial vibration.
Possible faults
Misalignment. The classic cause: a strong 2×, parallel or angular, usually with raised axial vibration.
Bent shaft. Can drive a prominent 2× alongside 1×.
Mechanical looseness. A loose fit that knocks twice per revolution.
Coupling issues. Wear or mismatch that excites 2×.
Secondary resonance. A natural frequency near 2× amplifying the peak.
How MultiViz detects it
MultiViz tracks the harmonics of running speed and compares the 2× level to the rest of the spectrum.
When 2× dominates, it flags Dominant 2×.
It reports the estimated RPM and the 1× and 2× levels over time, so a developing misalignment is easy to catch before it loads up the bearings and coupling.