A sub-synchronous pattern appears when the dominant envelope peak (or family of peaks) sits below 1× RPM, meaning its order is less than 1.
Characteristics
Slower than the shaft. A typical order is around 0.3–0.5: the event repeats only every two or three revolutions.
Rare, so telling. Almost nothing on a healthy machine produces this. When it appears, it usually points to a specific, identifiable mechanism.
Why the envelope. High-frequency bursts are demodulated down to their slow repetition rate, making the sub-synchronous pattern visible.
Possible faults
Bearing cage damage (FTF). The cage rotates at ~0.3–0.4× RPM. Cage failures also have the shortest path to catastrophic damage.
Oil whirl / whip. Whirl appears at ~0.42–0.48×; if it locks onto the rotor’s natural frequency as speed rises, it becomes the more severe oil whip.
Belt-drive faults. Belt frequency always falls below either pulley’s RPM; worn or mismatched belts appear as sub-synchronous harmonics.
Rotor rub. Typically sub-harmonics at 1/2× or 1/3× with a truncated time waveform.
Loose rolling elements / lubrication issues. Can also leak sub-synchronous content into the envelope.
How MultiViz detects it
MultiViz scans the squared envelope spectrum and classifies each peak family by order.
Any family with a fundamental below 1× is flagged as Sub-synchronous Envelope Harmonics.
Each detection reports the estimated RPM, the fundamental order and all harmonic orders, so 0.40× suggests a cage fault, 0.45× suggests oil whirl, and a belt frequency is recognisable at a glance.