Symptom: Dominant 2× Line Frequency

ARTICLE Last updated:
Release Note published:
November 12, 2026

Definition

Electric motors vibrate at twice the electrical line frequency (100 Hz on a 50 Hz supply, 120 Hz on 60 Hz) because the magnetic pull on the rotor peaks twice per AC cycle. The symptom is flagged when that 2×LF peak is strong relative to the rest of the spectrum.

Characteristics

  • Electrical, not mechanical. 2×LF is tied to the power supply rather than the shaft speed, so it usually doesn’t line up with the RPM harmonics.
  • The confirmation trick. Cut the power and a true electrical peak disappears instantly, while a mechanical peak coasts down with the shaft.

Possible faults

A strong 2×LF means the magnetic field in the motor is uneven. The most common causes:

  • Stator problems. An eccentric stator or shorted laminations creating an uneven air gap.
  • Air-gap eccentricity / soft foot. An uneven mounting distorts the air gap and drives 2×LF.
  • Rotor bar problems. Broken or cracked bars, often with line-frequency sidebands.
  • Phase / connection issues. An unbalanced supply or loose electrical connections.

How MultiViz detects it

  • MultiViz looks specifically for energy at twice the line frequency, separately from the running-speed harmonics.
  • When that 2×LF component is strong relative to the spectrum, it flags Dominant 2× Line Frequency.
  • Because the electrical order is separated from the mechanical ones, it is clear to check the motor and its mounting rather than the driven machine.

What it looks like

Dominant 2X line frequency symptom example

See all 11 symptoms in the Symptoms overview.