Electric motors vibrate at twice the electrical line frequency (100 Hz on a 50 Hz supply, 120 Hz on 60 Hz) because the magnetic pull on the rotor peaks twice per AC cycle. The symptom is flagged when that 2×LF peak is strong relative to the rest of the spectrum.
Characteristics
Electrical, not mechanical. 2×LF is tied to the power supply rather than the shaft speed, so it usually doesn’t line up with the RPM harmonics.
The confirmation trick. Cut the power and a true electrical peak disappears instantly, while a mechanical peak coasts down with the shaft.
Possible faults
A strong 2×LF means the magnetic field in the motor is uneven. The most common causes:
Stator problems. An eccentric stator or shorted laminations creating an uneven air gap.
Air-gap eccentricity / soft foot. An uneven mounting distorts the air gap and drives 2×LF.
Rotor bar problems. Broken or cracked bars, often with line-frequency sidebands.
Phase / connection issues. An unbalanced supply or loose electrical connections.
How MultiViz detects it
MultiViz looks specifically for energy at twice the line frequency, separately from the running-speed harmonics.
When that 2×LF component is strong relative to the spectrum, it flags Dominant 2× Line Frequency.
Because the electrical order is separated from the mechanical ones, it is clear to check the motor and its mounting rather than the driven machine.